General
-
We decided to not provide a printed user manual with every kit to reduce waste and contribute to sustainable science. You can find a QR code inside the kit to download the user manual You can also find the manuals on our website under "Download Center" or under the "Product Resources" section in the "Our Products" dropdown.
You can find a QR code inside the kit to download the user manual. You can also find manuals on the corresponding product page under “Product Resources”.
-
Please request the SDS via QA@bioecho.de or contact your Sales Representative.
-
Please request the CoA via QA@bioecho.de or contact your Sales Representative.
Benefits & Features
-
We do not use organic solvents such as ethanol during our extraction, so forget about the carry-over of such components in your nucleic acid extraction.
We reduce the use of hazardous reagents to a minimum so you will have a user and environmentally friendly product.
The EchoLUTION technology is a single-step purification method, which makes it faster compared to conventional methods. Say goodbye to bind-wash-elute methods, and welcome EchoLUTION in your laboratory routine.
If you need further information, visit our technology page.
-
We have two types of tailored lysis in our products, which have been adapted to the specific sample inputs.
If you need further information, visit our technology page. If you have specific questions, please reach out to support@bioecho.de
-
There are several ways you can benefit by switching to BioEcho; here are just a few:
The EchoLUTION technology is a single-step purification, which makes it faster compared to conventional methods.
Due to the reduced number of steps and less packaging, EchoLUTION is a sustainable choice.
EchoLUTION uses a different technology than magnetic beads and silica methods, which means it might work better for samples for which these methods do not work well.
If you would like to know more about the advantages of using BioEcho products, visit our technology page, or check out our technology video.
Reduce associated costs to your nucleic acid extraction like consumables or waste disposals.
Find more information here.
-
We see sustainability as a holistic approach. Therefore, every department contributes to an environmentally friendly business. Here are some examples:
Marketing and Sales: Fewer printed marketing materials User manuals are only available online!
Supply Chain Management: Preference for suppliers from Germany and Europe to reduce the carbon footprint.
Manufacturing: Reusable kit components can be purchased separately.
Purchasing: Suppliers requested to reduce unnecessary packaging materials.
If you want to learn more about our sustainability concept, you can get more information in our sustainability brochure.
-
With our innovative EchoLUTION technology, we invented a sustainable method to isolate nucleic acids from a variety of different sample types. Thereby we reduced the established "bind-wash-elute" workflow to a single-step purification workflow. As a result, we reduce consumables (such as tips), liquid waste, hands-on time, hands-on steps. Depending on the product, plastic consumption can be reduced by up to 70% compared to other established nucleic acid isolation methods.
For more information, we invite you to read our sustainability brochure. If you want to know in detail about cost savings, you can find this information in this case study.
Technical Questions
-
Following our sustainable approach, we do not include reusable components, such as the Conditioning Plate in our kits as they can be reused several times. These reusable components are purchased separately. To purchase them, please make sure to select the correct ones depending on the format. For 96-well plates click here, for 384-well plates click here and for diagnostic products click here.
-
Spin column products can be performed in a microcentrifuge with a rotor for 2 mL reaction tubes. The centrifuge must be capable of reaching at least 3,900 x g.
For our FFPE products, the microcentrifuge must reach a speed of 19,000 x g for the phase separation. Spin column products can also be processed with a plate centrifuge with swing-out rotors. When using a plate centrifuge, please remember to use our Spin Column Adapter for Plate Centrifuges (product number 050-011-024)Plate formats require a plate centrifuge with a swing-out rotor capable of 3,900 x g (minimum 1,500 x g) and buckets that hold plate stacks of 5 cm.
If you have further questions about the specifications for centrifugation, please contact us at support@bioecho.de
-
The plate stacks used during conditioning (Purification Plate and Conditioning Plate) have a height of 5 cm for the 96-well formats and 3.5 cm for the 384-well formats. For purification, the plate stacks have a height of 4.5 cm and 3.5 cm for the 96- and 384-well formats, respectively.
If you have further questions about our plate specifications, please contact us at support@bioecho.de.
-
Yes, with our 96-well-format Kits a partial plate usage is possible. Please contact support@bioecho.de for a detailed instruction.
-
The EchoLUTION technology is a new way of nucleic acid extraction based on a different purification principle and chemistry (buffer solutions) than the silica or magnetic bead-based method, which might make them incompatible.
Therefore, we do not recommend using nor mixing vendor chemistries. Additionally, we would not be able to support you or do correct troubleshooting if you have problems with nucleic acid quantity, quality, or performance in downstream applications. -
As different kits use different purification matrices, depending on the sample type, we recommend using only the Spin Columns and Purification Plate specified for each sample type. Using a column or plate from another EchoLUTION kit could result in insufficient quality, quantity, and performance in downstream applications. If you have any questions, please contact us at support@bioecho.de
-
Unfortunately, this is not possible. Using a higher lysate volume than the recommended in the user manuals can result in incomplete removal of unwanted components and inhibitor carryovers. Please ensure that you are working with the loading volumes specified in the specific manual.
-
To ensure optimal performance of the purified nucleic acids, we recommend directly preparing your downstream applications, such as PCR, RT-PCR, or NGS. If not possible, store RNA samples at –80°C and DNA at –20°C to preserve their integrity. Additionally, minimize freeze-thaw cycles to prevent potential nucleic acid degradation. Nucleic acids are stable at the mentioned temperature for at least 1 year.
-
A demo offers you the best chance to evaluate if we are the right partner for you! You’ll get the product for free and invest only a minimum of time to get a thorough introduction to our technology. Also, we see our demos as a safe space to ask any questions. We will be onsite to provide tips and tricks and optimize or troubleshoot your workflow. If you would like to have a demo click here.
-
For some applications a reduction of the loading volume is possible. For more information please contact support@bioecho.de.
-
The adhesive foil is used during incubation periods. This foil is air-permeable and avoids cross-contamination. For that reason the Adhesive Foil is not suitable for sample storage, as Eluate can evaporate.
Trouble-
shooting
-
No, it is not. Air bubbles might indicate an inappropriate spin column preparation. To homogenize the matrix in the spin columns, the spin columns need to be vortexed thoroughly. You can perform this step in an upright position, on the side, or upside down depending on what works best for you. If air bubbles are visible, it is mandatory to remove them completely. To remove air bubbles, place spin columns in a 2 mL reaction tube and spin down at 1,000 x g for 1 minute. For improved sedimentation of the matrix, we recommend that this step is performed upon receipt of the kit and store them in an upright position.
-
A highly tilted matrix after conditioning can result in poor extraction performance. However, when using fixed-angle rotor centrifuges, the matrix does not become fully horizontal after conditioning. A slightly tilted surface according to the angle of the rotor (usually 30°) is to be expected, and this does not limit the purification ability. But if you observe that the matrix is tilted to a higher angle, we recommend placing the spin columns in a 2 mL reaction tube and spin down at 1,000 x g for 1 minute. For improved sedimentation of the matrix, we recommend that this step is performed upon receipt of the kit and store them in an upright position. Another reason could be that the spin column was completely closed during centrifugation and a vacuum was generated. Alternatively, we suggest using a swing-out rotor centrifuge with our Spin Column Adapter for Plate Centrifuges (product number: 050-011-024).
-
In general, we recommend our customers avoid prolonging the incubation time or the temperature during lysis. Our products have different types of tailored lysis depending on the sample input (see image). For the kits with an ultra-fast lysis type, we strongly recommend sticking to the time and heat mentioned in the user manual for these products, as an increase in time and temperature can lead to nucleic acid degradation. Our FFPE products with xylene-free decrosslinking and deparaffinization, differs from other products on the market, which perform overnight lysis, we do not recommend prolonging the incubation time either as this might lead to nucleic acid fragmentation and degradation. If you have further questions, please contact us at support@bioecho.de
-
Heat-shaking is a crucial step to guarantee an optimal lysis. However, if you do not have a heat-shaker instrument or would like to know if you can use an alternative method, please contact us at support@bioecho.de. We have had several customers that use different alternatives, and we might be able to support you here with some options.
-
Our products are available in spin columns, 96- and 384-well plate formats, giving you the flexibility to go from a low to a mid and high throughput. With our EchoLUTION Cell Culture RNA and EchoLUTION Plant DNA 384 formats, you can purify four times 96 samples within one centrifugation step of one minute. You cannot go faster than that!
If you have a project where you would like to scale up your throughout, please contact us at support@bioecho.de
-
The coloration of the eluate may indicate column overloading. If you see effects in your downstream application when using colored eluates, the amount of sample used should be reduced. Here you can find a nice overview of known PCR inhibitors from different sample types.
If decreasing your sample input does not help, please contact our specialists at support@bioecho.de -
The DNA integrity number (DIN) and RNA integrity number (RIN) determine the integrity and degradation of nucleic acids. Different from the DV200, which evaluates the percentage of RNA fragments above 200 nucleotides.
-
Yes, our EchoLUTION Tissue DNA Kit works with samples stabilized in ethanol, formaldehyde, and RNA stabilization buffers like PurifyLater and RNAlater. If you would like to know more about this, and get a working protocol, please contact our specialists at support@bioecho.de
-
Yes, it is possible to automate our EchoLUTION plate formats (96- and 384-well plates). To meet the needs of our customers and help them increase their throughput with high reproducibility, we have worked on different fully or semi-automated solutions for our products.
If you would like to get more information about automation or would like to work together to develop a tailored automated protocol, contact our specialists at support@bioecho.de -
Our RNA extraction kits have been shown to efficiently extract miRNAs. For further information please refer to the product information or contact us at support@bioecho.de
-
If one of the Lysis Buffers in the chart below is stored at 2–8 °C, a precipitate might form. Please leave the buffer at room temperature for a few minutes until the white precipitate has dissolved. If necessary, you can heat the buffer up to 56 °C for a few minutes to fully dissolve the precipitate.
All listed buffers contain SDS, which precipitates cloudy when stored at 2-8°C in the fridge.
Lysis Buffer
Lysis Buffer Tissue DNA
Lysis Buffer Tissue RNA
Lysis Buffer FFPE
Lysis Buffer Plant
Lysis Solution Cell RNA
Lysis Solution Buccal Swab DNA
Shipment
& Logistics
-
Most of our products are shipped at room temperature. Upon arrival, please check the labels as some components might be stored at 2–8°C. Some of our RNA products have components that are shipped cold, please make sure to store them at –20°C upon arrival.
-
We ship worldwide! You can find our official distributors here. If your country is not listed, you can send your order to orders@bioecho.eu.
-
When your order is shipped, you will receive a shipping notification e-mail that contains the tracking number for your shipment so you can track your order real time. If you still have questions, please contact us at orders@bioecho.eu.